| Designator | SBC65e |
| Material | Cast-in-Place Concrete (C) |
| Test Specification | AASHTO MASH 2009 |
| Test Level | TL-5 |
| Perm/Temp | Permanent |
| Mounting Type | Deck |
| Deck Type | Conventional Reinforced Concrete |
| Aesthetic | No |
| See-Through | No |
| Retrofit | No |
| Combo Traffic/Pedestrian | No |
| Contact | Midwest Roadside Safety Facility |
| Drawing Status | Review Complete |
| Manufacturer | Non-Proprietary |
| FHWA Eligibility Letter | |
| Components | |
| Drawings | SBC65e - Test Section Details.pdf SBC65e - Typical Sections.pdf SBC65e_draft20160927.pdf |
| Other Docs | SBC65e - Crash Test Report - TRP-03-356-16.pdf SBC65e Test Video - Behind Rail.wmv SBC65e Test Video - Front View.wmv SBC65e Test Video - Overhead.wmv SBC65e Test Video - Rear View.wmv |
| Archive | |
| External Links |
Manitoba Constrained-Width Tall-Wall Bridge Railing
|
0