| Designator | SBW04c |
| Material | W-Beam (W) |
| Test Specification | AASHTO MASH 2016 |
| Test Level | TL-3 |
| Perm/Temp | Permanent |
| Mounting Type | Side |
| Deck Type | Conventional Reinforced Concrete |
| Aesthetic | No |
| See-Through | Yes |
| Retrofit | Yes |
| Combo Traffic/Pedestrian | No |
| Contact | Midwest Roadside Safety Facility |
| Drawing Status | Review Complete |
| Manufacturer | Non-Proprietary |
| FHWA Eligibility Letter | B-228.pdf |
| Components | Guardrail Bolt & Recessed Nut 6-inch W-Beam Backup Plate Square Guardrail Washer Class 4.6 Hex Bolt & Nut Hex Nuts 4-Space W-Beam Guardrail Class 4.6 Hex Bolt & Nut Post and Standoff for Weak-Post in Socket |
| Drawings | MGS Bridge Rail Drawing (Solidworks eDrawing).EDRW MGS Bridge Rail Drawing (pdf).pdf SBW04c_draft20150729.pdf |
| Other Docs | 11-2687 - MGS Bridge Rail TRB Paper.pdf |
| Archive | |
| External Links |