Designator and Name |
Image |
Material | Test Specification | Test Level | Perm/Temp | Mounting Type | Deck Type | Aesthetic | See-Thru | Retrofit | Combo | Contact |
---|---|---|---|---|---|---|---|---|---|---|---|---|
SBW09c31-inch W-Beam Guardrail on Low-Fill Box Culvert | ![]() | W-Beam (W) | AASHTO MASH 2016 | TL-3 | Permanent | Box Culvert | No | No | No | No | Texas A&M Transportation Institute | |
SBC03bAesthetic Baulstrade Bridge Railing | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Conventional Reinforced Concrete | Yes | Yes | No | No | Texas A&M Transportation Institute | ||
SBM04dAIMS Liferail Retrofit Bridge Rail | ![]() | Other Material (M) | AASHTO MASH 2016 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | Yes | No | Asset Integrity Management Solutions, LLC |
SBB50dAlaska MASH 2-Tube Bridge Rail | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Alaska Department of Transportation |
SBB04cAnnisquam River Bridge | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-3 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | |
SBM03bBaltimore-Washington Parkway Railing | ![]() | Other Material (M) | NCHRP Report 350 | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | No | No | No | Maryland Department of Transportation |
SBO02dBronx-Whitestone Median Barrier Extension Bridge Rail | ![]() | Other Steel (O) | AASHTO MASH 2016 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | New York Metropolitan Transportation Authority |
SBC13dCA Type 732 | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | No | Yes | No | California Department of Transportation |
SBC12dCA Type 80 | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | California Department of Transportation |
SBC12bCA Type 80 SW | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | No | Yes | California Department of Transportation |
SBB16dCA Type ST-10 | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | Yes | No | California Department of Transportation |
SBB42dCA Type ST-20 | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | Yes | No | California Department of Transportation |
SBB43dCA Type ST-30 | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | No | No | California Department of Transportation |
SBB44dCA Type ST-40 (NETC 4-Bar) | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | Yes | Yes | No | Yes | California Department of Transportation |
SBC63bCalifornia Type 732SW Bridge Railing | ![]() | Cast-in-Place Concrete (C) | AASHTO MASH 2016 | TL-2 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | No | No | Yes | California Department of Transportation |
SBB41dCalifornia Type 90 Concrete/Steel Bridge Railing | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | Yes | No | California Department of Transportation |
SBB53dColorado Type 10 Bridge Rail | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Colorado Department of Transportation |
SBC68eConstant Slope Barrier on Cantilevered Bridge Deck with Noise Wall | ![]() | Cast-in-Place Concrete (C) | AASHTO MASH 2016 | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | WSP USA, Inc. |
SBC64cConti Half-Shape Concrete Temporary Bridge Railing | ![]() | Precast Concrete (C) | AASHTO MASH 2016 | TL-3 | Temporary | Deck | Conventional Reinforced Concrete | No | No | No | No | Conti Enterprises, Inc. |
SBD01aCurb-Type Timber Bridge Rail | ![]() | Wood (D) | NCHRP Report 350 | TL-1 | Permanent | Deck | Longitudinal Glue-Laminated Wood | Yes | Yes | No | No | Midwest Roadside Safety Facility |
SBT04dDL Thrie Beam Retrofit | Thrie-Beam (T) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | Yes | No | Delaware Department of Transportation | |
SBA07dEdgeRail | ![]() | Aluminum (A) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | Yes | Yes | No | No | Hill & Smith PLC |
SBC69eF-Shape Barrier on Cantilevered Bridge Deck with Noise Wall | ![]() | Cast-in-Place Concrete (C) | AASHTO MASH 2016 | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | WSP USA, Inc. |
SBC52dFL 42" Vertical Wall | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Florida Department of Transportation |
SBA02bFoothills Parkway Bridge Railing | ![]() | Aluminum (A) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | No | No | Valentine & Company |
SBC08dGA One-Pipe Combo Rail | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | Yes | Georgia Department of Transportation |
SBC09bGA Two-Pipe Combo Rail | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | Yes | Georgia Department of Transportation |
SBD04aGlacier Removable Bridge Railing | ![]() | Wood (D) | NCHRP Report 350 | TL-1 | Both | Side | Conventional Reinforced Concrete | Yes | Yes | No | No | Federal Highway Administration |
SBD07aGlue-Laminated Wood Curb Railing | ![]() | Wood (D) | NCHRP Report 350 | TL-1 | Deck | Longitudinal Glue-Laminated Wood | Yes | Yes | No | No | Midwest Roadside Safety Facility | |
SBC70cHawaii 34" Tall Aesthetic Concrete Bridge Rail | ![]() | Cast-in-Place Concrete (C) | AASHTO MASH 2016 | TL-3 | Permanent | Deck | Conventional Reinforced Concrete | Yes | No | No | No | Hawaii Department of Transportation |
SBC71cHawaii 42" Tall Aesthetic Concrete Bridge Rail | ![]() | Cast-in-Place Concrete (C) | AASHTO MASH 2016 | TL-3 | Permanent | Deck | Conventional Reinforced Concrete | Yes | No | No | No | Hawaii Department of Transportation |
SBC24bIA Retrofit Concrete | ![]() | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | No | No | Yes | No | Midwest Roadside Safety Facility |
SBB19dIL 2399 | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | |
SBB39dIllinois Side Mounted Steel Railing | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Side | Conventional Reinforced Concrete | No | Yes | No | No | ||
SBB11dIN Steel Tube Bridge Rail PS-1 | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | Yes | ||
SBB10bIN Steel Tube Bridge Rail PS-2 | Steel Tube/Box (B) | NCHRP Report 350 | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | Yes | ||
SBC53bLow-Profile Concrete Bridge Railing | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | Yes | Yes | No | No | Midwest Roadside Safety Facility |
SBB45dMaine 36" 3-Tube Bridge Railing | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | Yes | Yes | No | No | ||
SBC65eManitoba Constrained-Width Tall-Wall Bridge Railing | ![]() | Cast-in-Place Concrete (C) | AASHTO MASH 2009 | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Midwest Roadside Safety Facility |
SBO01dMDS-4 | ![]() | Other Steel (O) | NCHRP Report 350 | TL-4 | Both | Deck | Conventional Reinforced Concrete | No | No | No | No | MDS LLC |
SBO01eMDS-5 | ![]() | Other Steel (O) | NCHRP Report 350 | TL-5 | Both | Deck | Conventional Reinforced Concrete | No | No | No | No | MDS LLC |
SBC67dMDTA Chesapeake Bay Bridge Concrete Rail System | ![]() | Cast-in-Place Concrete (C) | AASHTO MASH 2016 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Maryland Transportation Authority |
SBO03eMDTA Chesapeake Bay Bridge Steel Rail System | ![]() | Other Steel (O) | AASHTO MASH 2016 | TL-5 | Permanent | Steel Floor Beam | Conventional Reinforced Concrete | No | No | No | No | Maryland Transportation Authority |
SBW04cMGS Bridge Rail | ![]() | W-Beam (W) | AASHTO MASH 2016 | TL-3 | Permanent | Side | Conventional Reinforced Concrete | No | Yes | Yes | No | Midwest Roadside Safety Facility |
SBB21cMI Open Parapet | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-3 | No | No | No | No | ||||
SBB20dMI Tubular Railing | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Michigan Department of Transportation |
SBB25dMI Two Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Michigan Department of Transportation |
SBC32dMI Type 5 | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Michigan Department of Transportation |
SBB04dMN Type 3 Combo Railing | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | Yes | |
SBC33dMN Type F with Bicycle Rail | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | Yes | Midwest Roadside Safety Facility |
SBT07cMO Thrie Beam | ![]() | Thrie-Beam (T) | NCHRP Report 350 | TL-3 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | |
SBB46dModified NETC 4-Bar for Through-Truss Bridges | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Steel Floor Beam | No | Yes | Yes | No | RoadSafe LLC | |
SBC07cNatchez Trace Bridge Rail | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-3 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | No | No | Federal Highway Administration |
SBA03cNC Two-Bar Metal Bridge Rail | ![]() | Aluminum (A) | AASHTO MASH 2016 | TL-3 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | No | No | North Carolina DOT |
SBC30eNDOR Aesthetic Concrete Bridge Railing | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-5 | Permanent | Conventional Reinforced Concrete | Yes | No | No | No | Midwest Roadside Safety Facility | |
SBC34bNE Concrete Beam | ![]() | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Midwest Roadside Safety Facility |
SBC35bNE Concrete Beam | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | |
SBT10cNE Tubular Thrie Beam | Thrie-Beam (T) | NCHRP Report 350 | TL-3 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | Federal Highway Administration | |
SBB03cNested W-Beam with Tubular Backup Culvert Rail (OH Type 5 w/ Tubular Backup) | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-3 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | RoadSafe LLC |
SBB38dNETC Two Rail | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | New England Transportation Consortium | |
SBC66dNJDOT Balustrade Pulaski Skyway Bridge Parapet | ![]() | Cast-in-Place Concrete (C) | AASHTO MASH 2016 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | Yes | No | New Jersey Department of Transportation |
SBA03bNorth Carolina Standard 1-Bar | ![]() | Aluminum (A) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Parapet | Other | Yes | Yes | No | No | North Carolina DOT |
SBC39cNV Safety Shape Parapet | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-3 | Permanent | Parapet | Conventional Reinforced Concrete | No | No | No | No | Nevada Department of Transportation |
SBB29dNY Five Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | Yes | New York State Department of Transportation |
SBB28dNY Four Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | New York State Department of Transportation |
SBB27dNY Three Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | New York State Department of Transportation |
SBB26dNY Two Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | New York State Department of Transportation |
SBD03bOK Timber Rail | Wood (D) | NCHRP Report 350 | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Oklahoma Department of Transportation | |
SBC40bOK TR1 | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Oklahoma Department of Transportation |
SBC02bOpen Profile Concrete Bridge Railing | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | Texas A&M Transportation Institute | |
SBC42dOR Parapet and Sidewalk | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Oregon Deptartment of Transportation |
SBB32dOR Three Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Oregon Deptartment of Transportation |
SBB30bOR Two Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-2 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Oregon Deptartment of Transportation |
SBB31dOR Two Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Side | Conventional Reinforced Concrete | No | Yes | No | No | Oregon Deptartment of Transportation |
SBC41dOR Vertical Parapet | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Oregon Deptartment of Transportation |
SBB01bOregon 2-Tube Curb-Mounted Bridge Railing | ![]() | Steel Tube/Box (B) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | |
SBB51dOregon 3-Tube Curb-Mounted Bridge Rail | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Oregon Deptartment of Transportation |
SBB54cPA 3-Rail Bridge Barrier | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-3 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | Yes | Yes | No | No | Pennsylvania Department of Transportation |
SBB48ePennDOT PA Bridge Barrier | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-5 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Pennsylvania Department of Transportation |
SBB48dPennDOT PA Type 10M Bridge Barrier | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Pennsylvania Department of Transportation |
SBC37dPrecast Bolt-Down Safety Shape | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | New Jersey Department of Transportation | |
SBC18bPrecast Clamp Crete | Precast Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-2 | Both | Deck | Conventional Reinforced Concrete | No | No | No | No | CLAMPCRETE Construction Systems | |
SBC17bPrecast Clamp Crete Parapet | Precast Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-2 | Both | Deck | Conventional Reinforced Concrete | No | No | No | No | CLAMPCRETE Construction Systems | |
SBB55eRK-19 Bridge Rail | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-5 | Permanent | Deck | Other | No | Yes | No | No | New York Metropolitan Transportation Authority | |
SBC21dSafety Shape with Combo Rail | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | Yes | Georgia Department of Transportation |
SBB03bSide-Mounted Rectangular Tube Bridge Railing | ![]() | Steel Tube/Box (B) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Side | Conventional Reinforced Concrete | No | Yes | No | No | |
SBT01bSide-Mounted Thrie-Beam Bridge Railing | ![]() | Thrie-Beam (T) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Side | Conventional Reinforced Concrete | No | Yes | No | No | |
SBW03cSide-Mounted W-Beam | ![]() | W-Beam (W) | AASHTO Guide Spec for Bridge Railings | TL-3 | Permanent | Side | Conventional Reinforced Concrete | No | Yes | No | No | Michigan Department of Transportation |
SBB07dTacoma Narrows Bridge | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Texas A&M Transportation Institute |
SBB49eThree-Rail Steel Bridge Rail with Curb | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-5 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | New York State Thruway Authority |
SBT02dThrie-Beam Rail for Wood Decks | ![]() | Thrie-Beam (T) | NCHRP Report 350 | TL-4 | Permanent | Side | Wood | No | Yes | No | No | Midwest Roadside Safety Facility |
SBB52eThrogs Neck Bridge Rail | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-5 | Permanent | Deck | Other | No | Yes | No | No | New York Metropolitan Transportation Authority |
SBD01bTL-2 Glulam Timber Bridge Railing | ![]() | Wood (D) | NCHRP Report 350 | TL-2 | Permanent | Deck | Transverse Glue-Laminated Wood | Yes | Yes | No | No | Midwest Roadside Safety Facility |
SBC04dTL-4 F-Shape Concrete Bridge Railing | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Florida Department of Transportation |
SBD01dTL-4 Glulam Timber Bridge Railing | ![]() | Wood (D) | NCHRP Report 350 | TL-4 | Permanent | Deck | Transverse Glue-Laminated Wood | Yes | Yes | No | No | Midwest Roadside Safety Facility |
SBC05dTL-4 Safety-Shape Concrete Bridge Railing | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Georgia Department of Transportation |
SBC04eTL-5 F-Shape Concrete Bridge Railing | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Florida Department of Transportation |
SBC05eTL-5 Safety-Shape Concrete Bridge Railing | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-5 | Permanent | Parapet | Conventional Reinforced Concrete | No | No | No | No | Georgia Department of Transportation |
SBC55cTL3 NC Vertical Wall | ![]() | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-3 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | North Carolina DOT |
SBB08cTL3 Ohio Box Beam | Steel Tube/Box (B) | NCHRP Report 350 | TL-3 | Permanent | Deck | No | No | No | No | Texas A&M Transportation Institute | ||
SBC55dTL4 NC Vertical Wall | ![]() | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | North Carolina DOT |
SBB47eTriborough Bridge and Tunnel Authority Bridge Railing | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-5 | Permanent | Deck | Other | No | Yes | No | Yes | New York Metropolitan Transportation Authority |
SBA04bTru-Beam Aluminum Bridge Railing | Aluminum (A) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | Valentine & Company | |
SBA05dTruss-Core F-Shape | ![]() | Aluminum (A) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Valentine & Company |
SBD02cTubular Steel-Backed Timber Railing | ![]() | Wood (D) | NCHRP Report 350 | TL-3 | Permanent | Deck | Conventional Reinforced Concrete | Yes | Yes | No | No | Texas A&M Transportation Institute |
SBW01bTubular W-Beam Bridge Railing (TX Type T6) | ![]() | W-Beam (W) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | Texas Department of Transporation |
SBC43bTX C411 | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | |
SBB35bTX Energy Absorbing Bridge Railing | Steel Tube/Box (B) | NCHRP Report 350 | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | Texas Department of Transporation | |
SBC07dTX F411 | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | Yes | Yes | No | No | Texas A&M Transportation Institute |
SBB06cTX T4 | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-3 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Texas A&M Transportation Institute |
SBC07bTX T411 | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-2 | Permanent | Parapet | Conventional Reinforced Concrete | Yes | Yes | No | No | Texas A&M Transportation Institute |
SBC47fTX T501 | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-6 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Texas Department of Transporation |
SBC47dTX T501 SW | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | No | No | No | Texas Department of Transporation |
SBC48fTX TT | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-6 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Texas Department of Transporation |
SBB34eTX TYpe C202 | Steel Tube/Box (B) | NCHRP Report 350 | TL-5 | Permanent | Parapet | Conventional Reinforced Concrete | No | Yes | No | No | Texas Department of Transporation | |
SBC44eTX Type HT | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | Texas Department of Transporation |
SBB56dTxDOT C2P Bridge Rail | ![]() | Steel Tube/Box (B) | AASHTO MASH 2016 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Texas Department of Transporation |
SBB40cTXDOT T77 | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-3 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | Yes | Yes | No | Yes | Texas Department of Transporation |
SBC01bVertical Concrete Wall TL-2 | ![]() | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Texas A&M Transportation Institute |
SBC01dVertical Concrete Wall TL-4 | ![]() | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Texas A&M Transportation Institute |
SBC01eVertical Concrete Wall TL-5 | Cast-in-Place Concrete (C) | AASHTO Guide Spec for Bridge Railings | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | No | No | No | Texas A&M Transportation Institute | |
SBC15dVertical Wall with Sidewalk | ![]() | Cast-in-Place Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Parapet | Conventional Reinforced Concrete | No | No | No | No | Georgia Department of Transportation |
SBC54cVertical-Face PCB for Composite Decks | ![]() | Precast Concrete (C) | AASHTO MASH 2016 | TL-3 | Temporary | Deck | Fiber-Reinforced Polymer Composite | No | No | Yes | No | Midwest Roadside Safety Facility |
SBA08dVGAN 400 Bridge Rail | ![]() | Aluminum (A) | AASHTO MASH 2016 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | Yes | Hill & Smith PLC |
SBC61dVisi-Barrier 32-in F Bridge Railing | ![]() | Precast Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | Yes | No | Transpo Industries, Inc. |
SBC60dVisi-Barrier 32-inch New Jersey Bridge Railing | ![]() | Precast Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | Yes | No | Transpo Industries, Inc. |
SBC62dVisi-Barrier 32-inch Single-Slope Bridge Railing | ![]() | Precast Concrete (C) | NCHRP Report 350 | TL-4 | Permanent | Deck | Conventional Reinforced Concrete | No | No | Yes | No | Transpo Industries, Inc. |
SBC61eVisi-Barrier 42-inch F Bridge Railing | ![]() | Precast Concrete (C) | NCHRP Report 350 | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | No | Yes | No | Transpo Industries, Inc. |
SBC60eVisi-Barrier 42-inch New Jersey Bridge Railing | ![]() | Precast Concrete (C) | NCHRP Report 350 | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | No | Yes | No | Transpo Industries, Inc. |
SBC62eVisi-Barrier 42-inch Single-Slope Bridge Railing | ![]() | Precast Concrete (C) | NCHRP Report 350 | TL-5 | Permanent | Deck | Conventional Reinforced Concrete | No | No | Yes | No | Transpo Industries, Inc. |
SBB02bW and Tube Beam Deck Mounted (Texas T101) | ![]() | Steel Tube/Box (B) | AASHTO Guide Spec for Bridge Railings | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | No | No | Texas Department of Transporation |
SBW07aW-Beam on Glulam Timber Deck | ![]() | W-Beam (W) | NCHRP Report 350 | TL-1 | Permanent | Side | Longitudinal Glue-Laminated Wood | No | Yes | No | No | Midwest Roadside Safety Facility |
SBW08aW-Beam with breakaway wood posts | ![]() | W-Beam (W) | NCHRP Report 350 | TL-1 | Side | Longitudinal Glue-Laminated Wood | Yes | Yes | No | No | Midwest Roadside Safety Facility | |
SBT09bWA 10-Ga Thrie Beam Retrofit | ![]() | Thrie-Beam (T) | NCHRP Report 350 | TL-2 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | Yes | No | Washington State Dept. of Transportation |
SBB18bWashington DC Historic Retrofit | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-2 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | Yes | No | Yes | No | |
SBD05aWest Virginia TL-1 Timber Curb-Type Bridge Barrier | ![]() | Wood (D) | AASHTO MASH 2016 | TL-1 | Permanent | Deck | Wood | Yes | Yes | No | No | Midwest Roadside Safety Facility |
SBW06bWV W-Beam Retrofit | ![]() | W-Beam (W) | NCHRP Report 350 | TL-2 | Permanent | Deck | Conventional Reinforced Concrete | No | Yes | Yes | No | West Virginia Dept. of Transportation |
SBB36cWY Two Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-3 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Texas A&M Transportation Institute |
SBB36dWY Two Tube | ![]() | Steel Tube/Box (B) | NCHRP Report 350 | TL-4 | Permanent | Curb/Sidewalk | Conventional Reinforced Concrete | No | Yes | No | No | Texas A&M Transportation Institute |